If you’re a 20-person engineering shop in Fairfax or a small subcontractor in DC with one Defense Department task order, the CMMC headlines this year have probably left you unsure what you actually owe. The short version: the Phase II rollout was suspended in July 2026, but CMMC for small contractors did not go away. Phase 1 self-assessments are still required, and the NIST SP 800-171 controls behind them are still in your contract.

It’s a common question for DC-area firms that do some federal work alongside their commercial clients. This post covers what’s in force today, what a small contractor should fix first, and what a self-assessment involves.

Where CMMC stands in November 2026

The Department of Defense (which now also uses the name Department of War) explains the current status on its About CMMC page. Phase 1 began on November 10, 2025. Phase II, which would have added required third-party (C3PAO) assessments to more contracts, was scheduled for November 10, 2026. On July 13, 2026, the department suspended Phase II and set up a CMMC reform task force.

What didn’t change matters more for a small firm:

  • Phase 1 self-assessment requirements remain in place.
  • The department says it will enforce NIST SP 800-171 Rev. 2 through self-assessments and select government-led assessments during the review.
  • The suspension does not remove your duty to protect information under DFARS clause 252.204-7012.

So if a solicitation includes a CMMC requirement, you still need a current status posted in the Supplier Performance Risk System (SPRS) before award. The final DFARS rule in the Federal Register is clear that contracting officers can’t award to an offeror without the required CMMC status in SPRS, and that primes must check a subcontractor’s status before flowing down FCI or CUI.

The pause gives you time. It doesn’t give you a pass.

FCI or CUI: the question that sets your level

Everything starts with what information you handle.

Federal Contract Information (FCI) is information not meant for public release that’s provided by or generated for the government under a contract. Think statements of work, internal project schedules or pricing you build for a DoD job. Simple payment details don’t count.

Controlled Unclassified Information (CUI) is information that a law, regulation or government-wide policy says must be safeguarded. Technical drawings, specifications and export-controlled data are common examples in engineering and manufacturing work.

Here’s how the two self-assessment levels compare today:

 Level 1 (Self)Level 2 (Self)
ProtectsFCICUI
Requirements15, from FAR clause 52.204-21110, from NIST SP 800-171 Rev. 2
How oftenSelf-assessment and affirmation every yearSelf-assessment every 3 years, affirmation every year
Open items (POA&M) allowed?NoYes, limited, closed within 180 days
Where results goSPRSSPRS

Most small contractors and subcontractors that only see FCI land at Level 1. If your prime sends you CUI, you’re looking at Level 2, and the jump in work is real. Your contract, or your prime, tells you which level applies. Don’t guess.

CMMC for small contractors: what to fix first

When we look at a small firm’s environment for CMMC readiness, these are the gaps we check first. None of them need exotic tools. They need someone to own them.

1. Find out where FCI and CUI actually live

Before you fix anything, map it. Which mailboxes receive contract documents? Which SharePoint or file share folders hold drawings? Does anyone keep project files on a personal laptop or a USB drive? CMMC scoping is based on the systems that process, store or transmit FCI or CUI, so a smaller, cleaner footprint makes every later step cheaper.

A lot of small firms find out at this stage that contract files are spread across email, a shared drive, two cloud storage apps and a few desktops. Pulling that into one controlled place is often the single biggest win.

2. Lock down accounts

Level 1 requires you to limit system access to authorized users and to identify and authenticate them. In practice that means:

  • every person has their own account, with no shared logins
  • former employees and old vendor accounts are removed
  • admin rights are limited to the people who need them
  • multifactor authentication is on for email and remote access

For Level 2, MFA becomes an explicit requirement under NIST SP 800-171. If you use Microsoft 365, our Microsoft 365 security checklist for small businesses covers the settings we check first.

3. Patch, protect and scan

The Level 1 list includes fixing system flaws in a timely way, using malicious code protection, keeping it updated, and running periodic and real-time scans. That’s basic endpoint hygiene: supported operating systems, automatic updates you can actually confirm, and managed antivirus or EDR on every machine that touches contract data.

4. Control the network edge and physical access

You need to monitor and control communications at your network boundary, keep public-facing systems separate from internal ones, and limit physical access to your systems. For a small office, that means a properly configured firewall, guest Wi-Fi kept off the business network, a locked network closet, and escorted visitors.

5. Write down what you do

Assessments look for evidence. A short system security plan, an asset list, and records of who has access to what go a long way. At Level 2, documentation is a big part of the effort, and it’s where many small firms underestimate the time.

6. Plan for incidents before you need to

DFARS 252.204-7012 already requires reporting cyber incidents to the DoD within 72 hours of discovery. If you don’t have a written plan, start with our guide to building an incident response plan for a small business, then add the DoD reporting steps.

Cloud choices: commercial Microsoft 365 or GCC High?

It’s a common question from DC-area contractors. If you only handle FCI, commercial Microsoft 365 configured well can usually support Level 1. If you handle CUI, DFARS 252.204-7012 expects cloud services that store CUI to meet requirements equivalent to the FedRAMP Moderate baseline, which is why many contractors look at Microsoft’s government clouds such as GCC High.

GCC High costs more and changes how you work with outside partners, so it’s a scoping decision, not a default. Some firms keep their commercial tenant for everyday work and put CUI in a separate, smaller environment. Others move the whole company. Talk it through with your prime and your compliance advisor before you buy licenses.

What a self-assessment actually involves

For Level 1, you go through each of the 15 requirements, confirm it’s met, and an affirming official (a senior person in your company) enters the results and an affirmation in SPRS. You’ll need an SPRS account through the PIEE portal and a CAGE code from SAM.gov. Then you repeat it every year.

For Level 2, you assess against all 110 NIST SP 800-171 Rev. 2 requirements, score yourself using the DoD assessment method, and post the results in SPRS. Some open items can go on a plan of action and milestones (POA&M), but they must be closed within 180 days.

The affirmation is a statement to the government that you comply. Treat it seriously. If your environment doesn’t match what you’ve affirmed, that’s a legal and contract risk, not just an IT problem.

How we help DC-area contractors

We’re a managed IT and cybersecurity provider based in Fairfax, serving businesses across Northern Virginia, Washington DC and Maryland. For contractors, we provide CMMC readiness support: mapping where contract data lives, fixing account, device and network gaps, setting up Microsoft 365 securely, and helping you gather the documentation a self-assessment needs. We’re not a C3PAO, and we don’t issue certifications. Our job is to get your systems ready and keep them that way. Contractors along the Dulles corridor can see our IT services in Sterling, VA.

You can read more on our governance and compliance services page, see how we approach cybersecurity for small businesses, or check our IT support for engineering firms. If you’re in the District, our managed IT services in Washington DC page covers how we support offices there.

A good first step is our free Microsoft 365 security scan. It shows where your accounts, sign-in settings and sharing stand, which covers several of the access basics CMMC Level 1 asks about. Call us at (703) 340-1110 to set one up.

Frequently asked questions

Is CMMC still required after the Phase II suspension?

Yes. The Department of Defense suspended Phase II on July 13, 2026, but Phase 1 self-assessment requirements remain in place. If a solicitation includes a CMMC requirement, you need a current status posted in SPRS before award, and DFARS 252.204-7012 still applies.

What CMMC level does a small contractor need?

It depends on the information you handle. Firms that only handle Federal Contract Information usually need Level 1, a yearly self-assessment against 15 requirements. Firms that handle CUI need Level 2, which covers all 110 NIST SP 800-171 Rev. 2 requirements. Your contract or prime sets the level.

Do subcontractors need CMMC?

Yes, when they will process, store or transmit FCI or CUI for the contract. Primes must flow the requirement down and check that a subcontractor has the right CMMC status before sharing that information. A subcontractor that never receives FCI or CUI does not need an assessment.

Can we use commercial Microsoft 365 for CMMC?

For FCI only, a well-configured commercial Microsoft 365 tenant can usually support Level 1. For CUI, DFARS 252.204-7012 expects cloud services equivalent to the FedRAMP Moderate baseline, so many contractors look at Microsoft’s government clouds such as GCC High or a separate enclave.

Is Xala Tech a CMMC certifier?

No. We are not a C3PAO and do not issue certifications. We provide CMMC readiness support: finding where contract data lives, fixing account, device and network gaps, securing Microsoft 365 and helping you prepare the documentation a self-assessment needs.

Select Your Package

Contact Xala Tech

Walid Wardak

CEO & Founder

Walid Wardak is the CEO & Founder of Xala Tech. He leads the organization with a focus on technological innovation, IT solutions, and the delivery of reliable services to clients. Having more than 25 years of experience in the field of IT, Cyber Security, and networking, and have achieved numerous industry certifications.


As Chief Executive Officer and Founder of Xala Tech, Walid leads the vision, strategy, and growth of a dynamic IT Service Provider dedicated to delivering secure, scalable, and innovative IT solutions. With deep expertise in infrastructure, cloud services, and cybersecurity, Walid established the company to help organizations modernize their technology environments and operate more efficiently. Under Walid’s leadership, the company has built a reputation for reliability, client-focused service, and technical excellence. Passionate about empowering businesses through technology, Walid continues to drive innovation, foster strong partnerships, and position the organization for long-term success in a rapidly evolving digital landscape.